dog felis catus (ATCC)
99
Structured Review
ATCC
dog felis catus
Dog Felis Catus, supplied by ATCC, used in various techniques. Bioz Stars score: 99/100, based on 3191 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dog+felis+catus/NCTC+clone+929/10__5740_slash_jaoacint__smpr2016__010-48-142-145
Average 99 stars, based on 3191 article reviews
Dog Felis Catus, supplied by ATCC, used in various techniques. Bioz Stars score: 99/100, based on 3191 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dog+felis+catus/NCTC+clone+929/10__5740_slash_jaoacint__smpr2016__010-48-142-145
Average 99 stars, based on 3191 article reviews
dog felis catus - by Bioz Stars,
2026-09
99/100 stars
Images
Related Articles
Bacteria:Article Title: AOAC SMPR 2016.012:Standard Method Performance Requirements (SMPRs) for Detection and Identification of Variola Virus Article Snippet: Acceptable minimum detection level (AMDL).— Predetermined minimum level of an analyte, as specified by an expert committee that must be detected by the candidate method at a specified probability of detection (POD).. The AMDL is dependent on the intended use. (Draft EN ISO/CD 161401: Microbiology of food and animal feeding stuffs—Method validation—Part 1: Terminology of method validation, vs 1703-2011) Exclusivity.—Study involving pure nontarget strains that are potentially cross-reactive that shall not be detected or enumerated by the tested method. (Draft EN ISO/CD 161401: Microbiology of food and animal feeding stuffs—Method validation—Part 1: Terminology of method validation, vs 1703-2011) Inclusivity.—Study involving pure target strains that shall be detected or enumerated by the alternative method. (Draft EN ISO/CD 16140-1: Microbiology of food and animal feeding stuffs—Method validation—Part 1: Terminology of method validation, vs 17-03-2011) Maximum time-to-assay result.—Maximum time to complete an analysis starting from the collection buffer to assay result.. Probability of detection (POD).—Proportion of positive analytical outcomes for a qualitative method for a given matrix at a specified analyte level or concentration with a ≥0.95 confidence interval [Appendix H: Probability of Detection (POD) as a Statistical Model for the Validation of Qualitative Methods, Official Methods of Analysis of AOAC INTERNATIONAL, 20th Ed., 2016]. Article Title: AOAC SMPR 2015.012 Article Snippet: Acceptable minimum identification level (AMIL).— Predetermined minimum level of an analyte, as specified by an expert committee, which must be detected and identified by the candidate method with a specified probability of identification (POI).. Exclusivity.—Study involving pure nontarget strains and species, which are potentially cross-reactive, that shall not be detected or identified by the test method.. Inclusivity.—Study involving pure target strains or species that shall be detected and identified by the alternative method. Article Title: AOAC SMPR 2015.013 Article Snippet: Acceptable minimum detection level (AMDL).— Predetermined minimum level of an analyte, as specified by an expert committee which must be detected by the candidate method at a specified probability of detection (POD).. Maximum time-to-result.—Maximum time to complete an analysis starting with recovery of toxins from the collection matrix and ending with the assay result.. Probability of detection (POD).—Proportion of positive analytical outcomes for a qualitative method for a given matrix at a specified analyte level or concentration with a ≥0.95 confidence interval. Article Title: AOAC SMPR 2016.009:Standard Method Performance Requirements (SMPRs) for DNA-Based Methods of Detecting Brucella suis in Field-Deployable, Department of Defense Aerosol Collection Devices Article Snippet: Acceptable minimum detection level (AMDL).— Predetermined minimum level of an analyte, as specified by an expert committee which must be detected by the candidate method at a specified probability of detection (POD).. Exclusivity.—Study involving pure nontarget strains, which are potentially cross-reactive, that shall not be detected or enumerated by the candidate method.. Inclusivity.—Study involving pure target strains that shall be detected or enumerated by the candidate method. Article Title: AOAC SMPR® 2016.006 Article Snippet: Acceptable minimum detection level (AMDL).—The predetermined minimum level of an analyte, as specified by an expert committee that must be detected by the candidate method at a specified probability of detection (POD).. Environmental factors.—For the purposes of this SMPR: Any factor in the operating environment of an analytical method, whether abiotic or biotic, that might influence the results of the method.. Exclusivity.—Study involving pure non-target strains, which are potentially cross-reactive, that shall not be detected or enumerated by the candidate method. Article Title: AOAC SMPR® 2016.007 Article Snippet: Paul S. Keim (Chair), Northern Arizona University David Wagner (Chair), Northern Arizona University Jessica Appler, HHS BARDA Timothy Bauer, Naval Surface Warfare Center Dahlgren Linda Beck, CBR Defense Concepts and Experimentation Branch, Naval Surface Warfare Center Julie Boylan, Defense Threat Reduction Agency Ryan Cahall, Censeo Insight Kenneth Damer, Northrop Grumman Electronic Systems Matthew Davenport, Department of Homeland Security Mats Forsman, FOI Sweden Steven H. Hinrichs, University of Nebraska Medical Center Katalin Kiss, ATCC Laura Maple, NSWC Stephen A. Morse, Centers for Disease Control and Prevention (Retired) Pejman Naraghi-Arani, InSilixa Corp. Jeannine Petersen, Centers for Disease Control and Prevention (CDC) Denise Pettit, N.C. Department of Health and Human Services Michael Retford, JBTDS JPM NBCCA Mark Scheckelhoff, DHS/OHA Sanjiv Shah, U.S. EPA Shanmuga Sozhamannan, DoD ECBC Scott G. Coates (Staff Liaison), AOAC INTERNATIONAL Intended Use: Laboratory or field use by Department of Defense trained operators Article Title: AOAC SMPR® 2016.008 Article Snippet: Luther Lindler (Chair), DHS Jessica Appler, HHS BARDA Jeff Ballin, ECBC Timothy Bauer, Naval Surface Warfare Center Dahlgren Linda Beck, CBR Defense Concepts and Experimentation Branch, Naval Surface Warfare Center Julie Boylan, Defense Threat Reduction Agency Robert Bull, Department of Homeland Security Ryan Cahall, Censeo Insight Kenneth Damer, Northrop Grumman Electronic Systems Matthew Davenport, Department of Homeland Security Christina Egan, NYSDOH Ken Gage, CDC Jennifer Gibbons, ECBC/Excet Ted L. Hadfield, HADECO, LLC Malcolm Johns, DHS Matthew Lesho, Luminex Laura Maple, NSWC Traci Pals, DTRA Robert Perry, University of Kentucky Michael Retford, JBTDS JPM NBCCA Mark Scheckelhoff, DHS/OHA Sanjiv Shah, U.S. EPA Shanmuga Sozhamannan, Critical Reagents Program David Wagner, Northern Arizona University David Watson, DTRA Patricia Worsham, USAMRIID Scott G. Coates (Staff Liaison), AOAC INTERNATIONAL Intended Use: Field-deployed use for analysis of aerosol collection filters and/or liquids Virus:Article Title: AOAC SMPR 2015.012 Article Snippet: Acceptable minimum identification level (AMIL).— Predetermined minimum level of an analyte, as specified by an expert committee, which must be detected and identified by the candidate method with a specified probability of identification (POI).. Exclusivity.—Study involving pure nontarget strains and species, which are potentially cross-reactive, that shall not be detected or identified by the test method.. Inclusivity.—Study involving pure target strains or species that shall be detected and identified by the alternative method. Article Title: AOAC SMPR 2015.013 Article Snippet: Acceptable minimum detection level (AMDL).— Predetermined minimum level of an analyte, as specified by an expert committee which must be detected by the candidate method at a specified probability of detection (POD).. Maximum time-to-result.—Maximum time to complete an analysis starting with recovery of toxins from the collection matrix and ending with the assay result.. Probability of detection (POD).—Proportion of positive analytical outcomes for a qualitative method for a given matrix at a specified analyte level or concentration with a ≥0.95 confidence interval. |